Your Daikin has stopped and shows a code — or the LED is blinking. This is the table we use ourselves, translated to human: what it means, what you can try without tools, and when to call.
Quick summary
The most frequent Daikin codes: A3 = drainage (try clearing the drain), E5 = compressor overload, U0 = refrigerant shortage (a leak), U4 = indoor-outdoor communication failure, A5 = coil protection. Send your code via WhatsApp (+34 617 307 409) for free orientation.
How to read the code on a Daikin
On most domestic Daikin remotes: hold the Cancel button (or Check, depending on series) for about 5 seconds — the display enters diagnostic mode and cycles codes; on the one matching the active fault, the unit gives a long beep. Units with an indoor display show the code directly. Note it in full (letter + number): the letter identifies the subsystem, the number the specific fault.
Table of frequent Daikin codes
| Code | Meaning | Can you try anything? | Severity |
|---|---|---|---|
| A1 | Indoor unit board | Cut power 5 min and restart | Medium — if it repeats, call |
| A3 | Condensate level / drainage | Check the drain isn't kinked or blocked | Low — common and cheap |
| A5 | Freeze protection / coil | Wash the filters; if it persists, something more | Medium |
| A6 | Indoor fan motor | Nothing useful without opening it | Medium |
| E1 | Outdoor unit board | 5-minute power reset | Medium-high |
| E5 | Compressor overload | Clear leaves/dust off the outdoor unit, give it shade | High — have it measured |
| E7 | Outdoor fan motor | Check nothing blocks the blades | Medium |
| F3 | High discharge temperature | Possible low gas — don't insist | High |
| H6 | Compressor position sensor | Reset; if it repeats, call | Medium-high |
| U0 | Refrigerant shortage (leak) | Nothing — switch off and call: running on damages the compressor | High |
| U2 | Abnormal supply voltage | Check whether other appliances misbehave; may be your wiring | Medium |
| U4 | Indoor ↔ outdoor communication | 5-minute reset; if it repeats, wiring or board | Medium-high |
Exact codes vary by series and year — always confirm in your model's manual, or send us the code with the unit's reference.
The proper reset (which sometimes fixes it)
Before calling anyone, the reset that actually works: cut the AC's breaker at the electrical panel (the remote is not enough), wait 5 minutes for the electronics to discharge, and re-arm. If the code was a one-off protection (a micro-cut, a storm, a spike), the unit comes back clean. If the code returns within minutes or hours, it is real: note it and message us — with the code and model we usually give a guide diagnosis by message, free.
FAQ
Daikin error codes: what they mean and what to do — FAQ
My Daikin shows U0 — can I keep using it?
Better not: U0 means refrigerant shortage, and a compressor running short of gas damages itself — the cheap fault (recharge after fixing the leak) becomes the expensive one (compressor). Switch off and message us.
Is code A3 serious?
It is one of the kind ones: a blocked condensate drain or a stopped pump. Normally solved in one visit (from €60) with a pressure flush — and prevented by the annual clean.
Why does my Daikin run but blink the LED?
Some warnings do not stop the unit: dirty filters, recommended maintenance or a logged minor fault. Read it with the remote procedure and send us the code — we tell you whether it is urgent or can wait for the annual check.
Specialist's guides
Guides
Code noted? Send it — orientation is free.
Photo of the code and the unit's model via WhatsApp — a guide diagnosis by message before booking anything.